11. Yuan T, Hu JY, Ong SL, Ng WJ (2003) Simultaneous analysis of five selected phenolic
xenoestrogens in water sample using solid phase extraction-gas chromatography-mass spectrometry. Chromatographia 58(9):643–648. https://doi.org/10.1365/s10337-003-0067-x
12. Byrne B, Stack E, Gilmartin N, O’Kennedy R (2009) Antibody-based sensors: principles,
problems and potential for detection of pathogens and associated toxins. Sensors (Switzerland)
9(6):4407–4445
13. Jokisaari JR, Hachtel JA, Hu X, Mukherjee A, Wang C, Konecna A, Lovejoy TC, Dellby N,
Aizpurua J, Krivanek OL, Idrobo JC, Klie RF (2018) Vibrational spectroscopy of water with
high spatial resolution. Adv Mater 30(36):1802702
14. Della Ventura B, Iannaccone M, Funari R, Pica Ciamarra M, Altucci C, Capparelli R,
Roperto S, Velotta R (2017) Effective antibodies immobilization and functionalized
nanoparticles in a quartz-crystal microbalance-based immunosensor for the detection of parathion. PLoS One 12(2):e0171754
15. Lemarchand K, Lebaron P (2002) Influence of mutation frequency on the persistence of
Salmonella enterica serotypes in natural waters. FEMS Microbiol Ecol 41(2):125–131
16. Park M-K, Oh J-H (2012) Rapid detection of E. coli O157:H7 on turnip greens using a modified
gold biosensor combined with light microscopic imaging system. J Food Sci 77(2):M127–
M134
17. Cassiède M, Daridon JL, Paillol JH, Pauly J (2010) Impedance analysis for characterizing the
influence of hydrostatic pressure on piezoelectric quartz crystal sensors. J Appl Phys 108
(3):034505
18. Buszewski B, Grzywinski D, Ligor T, Stacewicz T, Bielecki Z, Wojtas J (2013) Detection of
volatile organic compounds as biomarkers in breath analysis by different analytical techniques.
Bioanalysis 5(18):2287–2306
19. Sauerbrey G (1959) Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur
Mikrowägung. Z Phys 155(2):206–222
20. OpenQCM. The first open source quartz crystal microbalance [Online]. https://openqcm.com
21. Mecea VM (2005) From quartz crystal microbalance to fundamental principles of mass
measurements. Anal Lett 38(5):753–767
22. Kanazawa KK, Gordon JG (1985) Frequency of a quartz microbalance in contact with liquid.
Anal Chem 57(8):1770–1771
23. Martin SJ, Frye GC, Ricco AJ, Senturia SD (1993) Effect of surface roughness on the response
of thickness-shear mode resonators in liquids. Anal Chem 65(20):2910–2922
24. Johannsmann D (1999) Viscoelastic analysis of organic thin films on quartz resonators.
Macromol Chem Phys 200:501–516
25. Janshoff A, Steinem C, Sieber M, El Bayâ A, Schmidt MA, Galla HJ (1997) Quartz crystal
microbalance investigation of the interaction of bacterial toxins with ganglioside containing
solid supported membranes. Eur Biophys J 26(3):261–270
26. Bottom VE (1982) Introduction to quartz crystal unit design. Van Nostrand Reinhold,
New York
27. Voinova MV, Jonson M, Kasemo B (2002) ‘Missing mass’ effect in biosensor’s QCM
applications. Biosens Bioelectron 17(10):835–841
28. Barnes C (1991) Development of quartz crystal oscillators for under-liquid sensing. Sensors
Actuators A Phys 29(1):59–69
29. Muckley ES, Anazagasty C, Jacobs CB, Hianik T, Ivanov IN (2016) Low-cost scalable quartz
crystal microbalance array for environmental sensing. Organic sensors and bioelectronics IX,
vol 9944. International Society for Optics and Photonics, San Diego, p 99440Y
30. Funari R, Della Ventura B, Carrieri R, Morra L, Lahoz E, Gesuele F, Altucci C, Velotta R
(2015) Detection of parathion and patulin by quartz-crystal microbalance functionalized by the
photonics immobilization technique. Biosens Bioelectron 67:224–229. https://doi.org/10.1016/
j.bios.2014.08.020
31. Arnau A (2008) A review of interface electronic systems for AT-cut quartz crystal microbalance
applications in liquids. Sensors 8(1):370–411
340
B. Della Ventura et al.
Précédent

- 355/357

Suivant