Table III
Summary of Projected Cost Estimate for Nickel Recovery by R.O. ('Closed Loop') System
Toronto Installation:
D= 15 gal/day:
W= 150 gal/day
Projected Scale:
D= 50 gal/day:
W = 500 gal/day
Projected Scale:
D = 500 gal/day:
W = 5000 gal/day
Flux Rate (gfd) at 450 psi
10.7
Permeation Rate (gal/day)
1,065
Nominal R.O. Unit Capacity (gal/day)
1,000
installed Capital Cost ($)
7,000
Amortized Capital Cost/1000 gal permeate
$6.96
*Operating & Maintenance Cost/1000 gal permeate
$0.70
Total Cost/1000 gal permeate
$7.66
Total Cost/day
$8.15
Recovered Value/day Ni
$9.46
Recovered Value/day as Total Salts
$ 16.62
Savings in Deionized Water Usage/day
$0.49
Total Savings as (Total Salts + Water)/day
$17.11
Net Savings/day
$8.96
10.7
3,550
3,500
9,000
$2.68
$3.40
$6.08
$21.60
$31.50
$55.30
$1.65
$56.95
$35.35
10.7
35,500
35,000
37,000
$1.03
$2.05
$3.08
$109.30
$315.00
$553.00
$16.50
$569.50
$460.20
Payback on Capital Investment
39 months
13 months
4 months
^Capital and Maintenance Costs can vary widely depending on the design of the unit.
Economic Plating Waste Treatment by Reverse Osmosis
Summary of Projected Cost Estimate for Nickel Recovery by R.O. ('Closed Loop') System
Toronto Installation:
D= 15 gal/day:
W= 150 gal/day
Projected Scale:
D= 50 gal/day:
W = 500 gal/day
Projected Scale:
D = 500 gal/day:
W = 5000 gal/day
Flux Rate (gfd) at 450 psi
10.7
Permeation Rate (gal/day)
1,065
Nominal R.O. Unit Capacity (gal/day)
1,000
installed Capital Cost ($)
7,000
Amortized Capital Cost/1000 gal permeate
$6.96
*Operating & Maintenance Cost/1000 gal permeate
$0.70
Total Cost/1000 gal permeate
$7.66
Total Cost/day
$8.15
Recovered Value/day Ni
$9.46
Recovered Value/day as Total Salts
$ 16.62
Savings in Deionized Water Usage/day
$0.49
Total Savings as (Total Salts + Water)/day
$17.11
Net Savings/day
$8.96
10.7
3,550
3,500
9,000
$2.68
$3.40
$6.08
$21.60
$31.50
$55.30
$1.65
$56.95
$35.35
10.7
35,500
35,000
37,000
$1.03
$2.05
$3.08
$109.30
$315.00
$553.00
$16.50
$569.50
$460.20
Payback on Capital Investment
39 months
13 months
4 months
^Capital and Maintenance Costs can vary widely depending on the design of the unit.
Economic Plating Waste Treatment by Reverse Osmosis