References
113
References
1. Wang J (2001) Glucose biosensors: 40 years of advances and challenges. Electroanalysis
13:983–988
2. Murphy L (2006) Biosensors and bioelectrochemistry. Curr Opin Chem Biol 10:177–184
3. Wang J (2008) Electrochemical glucose biosensors. Chem Rev 108:814–825
4. Zhang X, Ju H, Wang J (2008) Electrochemical sensors, biosensors and their biomedical
applications. Academic Press
5. Clark LC, Lyons C (1962) Electrode systems for continuous monitoring in cardiovascular
surgery. Ann N Y Acad Sci 102:29–45
6. Kaisti M (2017) Detection principles of biological and chemical FET sensors. Biosens
Bioelectron 98:437–448
7. Syu YC, Hsu WE, Lin CT (2018) Review-field-effect transistor biosensing: devices and clinical
applications. ECS J Solid State Sci Technol 7:Q3196–Q3207
8. Xia H-Q, Kitazumi Y, Sirai O, Kano K (2017) Direct electron transfer-type bioelectrocatalysis
of peroxidase at mesoporous carbon electrodes and its application for glucose determination
based on bienzyme system. Anal Sci 33:839–844
9. Emr SA, Yacynych AM (1995) Use of polymer films in amperometric biosensors and
chemically modified electrodes. Electroanalysis 7:357
10. Sasso SV, Pierce RJ, Walla R, Yacynych AM (1990) Electropolymerized 1, 2-Diaminobenzene
as a means to prevent interferences and fouling and to stabilize immobilized enzyme in
electrochemical biosensors. Anal Chem 62:1111–1117
11. Nieh CH, Tsujimura S, Shirai O, Kano K (2013) Amperometric biosensor based on reductive
H 2 O 2 detection using pentacyanoferrate-bound polymer for creatinine determination. Anal
Chim Acta 767:128–133
12. Nieh CH, Kitazumi Y, Shirai O, Kano K (2013) Sensitive d-Amino acid biosensor based on
oxidase/peroxidase system mediated by pentacyanoferrate-bound polymer. Biosens Bioelectron 47:350–355
13. Zhang X, Ju H, Wang J (2008) Electrochemical sensors, biosensors and their biomedical
applications. Academic Press. https://doi.org/10.1016/B978-0-12-373738-0.X5001-6
14. Levich VG (1942) The theory of concentration overpotential. Acta Physicochim URSS 17:257–
307
15. Saito Y (1968) A theoretical study on the diffusion current at the stationary electrodes of
circular and narrow band types. Rev Polarogra 15:177–187
16. Szabo A, Cope DK, Tallman DE, Kovach PM, Wightman RM (1987) Chronoamperometric
current at hemicylinder and band microelectrodes: theory and experiment. J Electroanal Chem
217:417–423
17. Kitazumi Y, Hamamoto K, Noda T, Shirai O, Kano K (2015) Fabrication and characterization
of ultrathin-ring electrodes for pseudo-steady-state amperometric detection. Anal. Sci. 31:603–
607
18. Noda T, Wanibuchi M, Kitazumi Y, Tsujimura S, Shirai O, Yamamoto M, Kano K (2013)
Diffusion-controlled detection of glucose with microelectrodes in mediated bioelectrocatalytic
oxidation. Anal Sci 29:279–281
19. Kitazumi Y, Noda T, Shirai O, Yamamoto M, Kano K (2014) Characteristics of fast mediated
bioelectrocatalytic reaction near microelectrodes. Phys Chem Chem Phys 16:8905
20. Matsui Y, Hamamoto K, Kitazumi Y, Shirai O, Kano K (2017) Diffusion-controlled mediated
electron transfer-type bioelectrocatalysis using microband electrodes as ultimate amperometric
glucose sensors. Anal Sci 33:845–851
21. Matsui Y, Kitazumi Y, Shirai O, Kano K (2018) Simultaneous detection of lactate enantiomers
based on diffusion-controlled bioelectrocatalysis. Anal Sci 34:1137–1142
22. Uchiyama S, Kobayashi Y, Suzuki S, Hamamoto O (1991) Selective biocoulometry of vitamin
C using dithiothreithol, N-Ethylmaleimide, and ascorbate oxidase. Anal Chem 63:2259–2262
Précédent

- 124/145

Suivant