seizure-free interval and 6985.755 for that patient at the time of seizure. Other
statistical parameters also revealed very clear results in distinguishing patient and
healthy individuals. However, the results of the STFT analyses support the statistical parameters. In this study, the frequency values of the healthy individual were
seen to distribute around 10 Hz, in the range of 0–5 Hz for the patient with epilepsy
at seizure-free interval and in the range of 0–20 Hz for that patient at the time of
seizure. Accordingly, it can be said that the statistical and spectral analyses made
are quite decisive for the diagnosis of the disease.
Author details
Furkan Kalin, T. Cetin Akinci*, Deniz Türkpence, Serhat Seker and Ufuk Korkmaz
Department of Electrical Engineering, Istanbul Technical University, Istanbul,
Turkey