13.6 Summary
469
(b)
(c)
Fig. 13.16 (continued)
(1) A box-like blast loading apparatus is designed to provide the one-way simplysupported boundary constraints of the test panels and avoid the effect of the
diffracted blast waves. Six reinforced UHPCC and NSC panels were fabricated and tested under medium-range explosions with the different scaled
distances from 0.5 to 1.0 m/kg
1/3 . The systematic data including the blastinduced incident and reflected overpressure-time histories, deflection- and
acceleration-time histories, as well as the post-blast damage of panels were
obtained.
(2) Under the medium-range explosion, the one-way test specimens mainly exhibit
the bending failure mode, and the damage of panels become more serious when
the scaled distance is reduced. Compared with the NSC panels, the UHPCC