Experimental Investigation of Heat Sinks with and Without …
281
4.3 Experiment with Six Fin-Based Perforated (8
and 10 mm) Heat Sink
Figure 6a, b, shows the geometrical details of 6 fin-based HS with 8 and 10 mm perforations. The convection coefficient values were found to increase with increase in heat
Fig. 6 a Fin configuration with 8-mm-based perforated heat sink. b Fin configuration with 10mm-based perforated heat sink