CHAPTER 18 . Metals Analysis by High Performance Liquid Chromatography
355
Nakahara T (1991) Hydride generation techniques and their applications in inductively-coupled plasma
atomic-emission spectrometry. Spectrochim Acta Rev 14:95-109
Ohashi H, Uehara N, Shijo Y (1991) Simultaneous determination of molybdenum, vanadium, gallium,
copper, iron and indium as quinolin-8-0Iate complexes by high-performance liquid chromatography. J Chromatogr 539:225-231
Ohtsuka C, Matsuzawa K, Wada H, Nakagawa G (1991) Chromatographic behaviour of 2-(2-pyridylazo)5-[N-(sulphoalkyl)amino]phenol chelates on hydrophobic stationary phases. Anal Chim Acta
252:181-186
Ohtsuka C, Matsuzawa K, Wada H, Nakagawa G (1992) Characterization of 2-(2-pyridylazo)-5-[N(sulphoalkyl)amino ]phenol derivatives as the pre-column chelating agent for trace metal determination by ion-pair reversed-phase liquid chromatography with spectrophotometric detection.
Anal Chim Acta 256:91-96
Ohtsuka C, Matsuzawa K, Wada H, Nakagawa G (1994) Retention behaviour of metal chelates in ionpair reversed-phase liquid chromatography as a function of mobile phase composition with methanol/water and acetonitrile / water mobile phases. Anal Chim Acta 294:69-74
Paull B, Jones P (1996) A comparative study of the metal selective properties of chelating dye impregnated resins for the ion-chromatographic separation of trace metals. Chromatographia 42:528-538
Paull B, Foulkes M, Jones P (1994a) Determination of alkaline earth metals in offshore oil-well brines
using high-performance chelation ion chromatography. Anal Proc 31:209-211
Paull B, Foulkes M, Jones P (1994b) High-performance chelation ion-chromatographic determination of trace metals in coastal sea water using dye-impregnated resins. Analyst 119:937-941
Paull B, Fagan PA, Haddad PR (1996) Determination of calcium and magnesium in sea water using a
dynamically coated porous graphitic carbon column with a selective metallochromic ligand as a
component of the mobile phase. Anal Commun 3P93-196
Paull B, Nesterenko P, Nurdin M, Haddad PR (1998) Separation of metal ions using a polymeric reversed-phase column and a methylthymol blue containing mobile phase. Anal Commun 35:17-20
Pitts L, Fisher A, Worsfold P, Hill SJ (1995) Selenium speciation using high-performance liquid chromatography-hydride generation atomic fluorescence with online microwave reduction. J Anal At
Spectrom 10:519-520
Porta V, Sarzanini C, Abollino 0, Mentasti E, Carlini E (1992) Pre-concentration and inductively-coupled plasma atomic-emission-spectrometric determination of metal ions with online chelating
ion exchange. J Anal At Spectrom 7:19-22
Posta 1, Berndt H, Luo SK, Schaldach G (1993) High-performance flow flame atomic-absorption
spectrometry for automated online separation and determination of chromium(III)/chromium(VI) and pre-concentration of chromium(VI). Anal Chern 65:2590-2595
Powell MJ, Boomer DW, Wiederin DR (1995) Determination of chromium species in environmental
samples using high-pressure liquid chromatography direct injection nebulization and inductivelycoupled plasma mass spectrometry. Anal Chern 67:2474-2478
Rauret G, Rubio R, Padr6 A (1991) Arsenic speciation using HPLC-hydride-generation ICP AES with
gas-liquid separator. Fresenius' Z Anal Chern 340:157-160
Rey MA, Riviello JM, Pohl CA (1997) Column switching for difficult cation separations. J Chromatogr
A 789:149-155
Riley JP, Taylor D (1968) Chelating resins for the concentration of trace elements from sea-water and
their analytical use in conjunction with atomic absorption spectrophotometry. Anal Chim Acta
40:479-485
Robards K, Starr P, Patsalides E (1991) Metal determination and metal speciation by liquid chromatography. Analyst 116:1247-1273
Rollin S, Kopatjtic Z, Wernli B, Magyar B (1996) Determination of lanthanides and actinides in uranium materials by high-performance liquid chromatography with inductively-coupled plasma
mass spectrometric detection. J Chromatogr 739:139-149
Rubio R, Padr6 A, Alberti J, Rauret G (1992) Speciation of organic and inorganic arsenic by HPLC -
HG - ICP [hydride-generation inductively-coupled plasma]. Mikrochim Acta 109:39-45
Ryan E, Meaney M (1992) Determination of trace levels of copper(II), aluminium(I1I) and iron(I1I)
by reversed-phase high-performance liquid chromatography using a novel online sample pre-concentration technique. Analyst 117:1435-1439
Sacchero G, Abollino 0, Porta V, Sarzanini C, Mentasti E (1991) Reversed-phase ion-interaction chromatography of metal ions by EDTA pre-complexation. Chromatographia 31:539-543
Sarzanini C, Mentasti E (1997) Determination and speciation of metals by liquid chromatography. J
Chromatogr A 789:301-321
Sarzanini C,Abollino 0, Mentasti E (1992) Hydroxyazo-dyes in metal ions preconcentration by ion exchange. In: Slater MJ (ed) Ion Exchange Advances. Elsevier Applied Science, London, pp 279-286
Précédent

- 362/447

Suivant