8.18 Sizing the Auxiliary Fan
369
drive to comply with regulations concerning maximum permitted air velocities in
underground works.
(x) Before providing any result, students should check, at least, if their answers lie
within the normal range. If we have a look at the last paragraph of Sect. 8.18, we
can see that auxiliary fans usually provide up to 28 m s
−1 at up to 3.7 kPa. Therefore, airflow requirements in the exercise are high. As the main reasons for this,
we can highlight the high level of leakage and the fact that estimates for the
machinery working in the tunnel at the same time could well be too large (the
use of simultaneity factors would have been more appropriate). Moreover, the
velocity at which air circulates inside the duct is above that generally recommended for this kind of duct (20 m s
−1 ). For this reason, it would be advisable
to modify the design, taking into account these considerations.
References
Andrade, S. (2008). Guía metodológica de seguridad para ventilación de minas. Chile: Departamento de Seguridad Minera. SERNAGEOMIN.
Audibert, M. M., & Dressler, J. (1946). Etude expérimentale du fonctionnement des canalisation
d´aérage secondarie. Revue de l´Industrie Minérale, 511 251–281.
ASM-51 (2010). Instrucción Técnica Complementaria. Explotación de capas de carbón por el
método de sutiraje desde subniveles en fondo de saco. BOPA n 67.
ASHRAE (2013). ASHRAE handbook-fundamentals. American Society of Heating. Refrigerating
and Air-Conditioning Engineers, Chapter 2. Atlanta, GA: Refrigerating and Air-Conditioning
Engineers, Inc.
Auld, G. (2004). An estimation of fan performance for leaky ventilation ducts. Tunnelling and
Underground Space Technology, 19(6), 539–549.
Bertard, C., & Bodelle, J. (1962). Chapitre IX. Aérage secondary. Aérage. Revue de l’Industrie
Minérale. Document SIM N2.
Borisov, S., Klokov, M. Y., & Gornovoi, B. (1976). Labores mineras. Moscú: Editorial Mir.
Brake, D. J. (2002). Fan total pressure or fan static pressure: Which is correct when solving
ventilation problems? Mine Ventilation Society of South Africa, 55(1), 6–11.
Carrier Corporation. Carrier Air Conditioning Company. (1965). Handbook of air conditioning
system design. Table 10. McGraw-Hill Companies.
Deniau, R. (1976). Aérage des quartiers exploités par chambres et piliers. En: Aérage. Document
SIM N3. Industrie Minérale. Mine 2–76.
de la Vergne, J. (2008). Hard rock miner’s handbook (5th ed.). Alberta: Stantec Consulting Ltd.
de Souza, E. M., & Katsabanis, P. D. (1991). On the prediction of blasting toxic fumes and dilution
ventilation. Mining Science and Technology, 13, 223–235.
de Souza, E. M. (2004). Auxiliary ventilation operation practices. In R. Ganguli & S. Bandopadhyay
(Eds.), Mine ventilation (pp. 341–349). Taylor & Francis Routledge.
Dick, R. A., Fletcher, L. R., & D’Andrea, D. V. (1982). Explosives and blasting procedures manual.
Washington, DC: US Department of the Interior, Bureau of Mines.
DuctSIM User´s Manual. (n.d.). Clovis, California: Mine Ventilation Services.
Expilly, P. (1960). Ventilation des Souterrains en Construction. Paris: Éditions Eyrrolles.
Flügge, G. (1953). Wirtschaftlichkeitsfragen der Sonderbewetterung. In Conference at Technische
Fachhochschule Georg Agricola.
Précédent