A Simplified Method for Conversion …
493
found that it is very easy to convert the surface model into solid model with the aid
of SolidWorks. The solid model can be further utilized in simulation software such
as ANSYS or Abaqus, to perform and calculate von Mises stress, strain as per the
researcher’s requirement. The suggested methodology will be very useful for the
researchers who are thinking to start their research in the field of spinal implantation.
Researchers can also perform the mesh sensitivity analysis to refine the results.
Moreover, the same procedure may be adopted to develop the other spinal region,
other body part surface and solid model.
References
1. Bianco R, Arnoux JP, Wagnac E, Mac-Thiong JM, Aubin CE (2017) Minimizing pedicle screw
pullout risks: a detailed biomechanical analysis of screw design and placement. Clin Spine Surg
30(3):E226–E232
2. Chen C-S, Huang C-H, Shih S-L (2015) Biomechanical evaluation of a new pedicle screwbased posterior dynamic stabilization device (Awesome Rod System)-a finite element analysis.
BMC Musculoskelet Disord 16(1):81
3. Ambati DV, Wright Jr EK Lehman Jr RA, Kang DG, Wagner SC, Dmitriev AE (2015) Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar
interbody fusion: a finite element study. Spine J 15(8):1812–1822
4. Divya V, Anburajan M (2011) Finite element analysis of human lumbar spine. In: 2011 3rd
international conference on electronics computer technology, vol 3. IEEE, pp 350–354
5. Wolf A, Shoham M, Michael S, Moshe R (2001) Morphometric study of the human lumbar
spine for operation–workspace specifications. Spine 26(22):2472–2477
6. Zhang QH, Teo EC (2008) Finite element application in implant research for treatment of
lumbar degenerative disc disease. Med Eng Phys 30(10):1246–1256
7. Teoh SH, Chui CK (2008) Bone material properties and fracture analysis: Needle insertion for
spinal surgery. J Mech Behav Biomed Mater 1(2):115–139
8. Biswas JK, Sahu TP, Masud R, Sandipan R, Karmakar SK, Santanu M, Amit R (2019) Design
factors of lumbar pedicle screws under bending load: a finite element analysis. Biocybernetics
Biomed Eng 39(1):52–62
9. Erbulut DU, Kiapour A, Oktenoglu T, Ozer AF, Goel VK (2014) A computational biomechanical investigation of posterior dynamic instrumentation: combination of dynamic rod and
hinged (dynamic) screw. J Biomech Eng 136(5)
10. Najafi-Ashtiani H, Najafi-Ashtiani M (2015) Comparative evaluation between rigid and
dynamic spinal fixation systems: a three-dimensional finite element analysis. Zahedan J. Res
Med Sci 17(8)
11. Jain P, Rajik Khan M (2019) Prediction of biomechanical behavior of lumbar vertebrae using a
novel semi-rigid stabilization device. Proc Inst Mech Eng, Part H: J Eng Med 233(8):849–857
12. Jain P, Rajik Khan M (2018) Biomechanical study of fused lumbar spine considering bone
degeneracy using FEA. Arab J Sci Eng 43(3):1325–1334
13. Jain P, Rajik Khan M (2020) Biomechanical study of lumbar spine (L2-L4) using hybrid
stabilization device-A finite element analysis. Int J Manuf Mater Mech Eng (IJMMME)
10(1):20–32
14. Jain P, Rana M, Biswas JK, Rajik Khan M (2020) Biomechanics of spinal implants–a review.
Biomed Phys Eng Express 6(4). https://doi.org/10.1088/2057-1976/ab9dd2
Précédent

- 485/502

Suivant