5. Heninger, I., Potin-Gautier, M., de Gregori, I., & Pinochet, H. (1997). Storage of aqueous
solutions of selenium for speciation at trace level. Fresenius Journal of Analytical
Chemistry, 357, 600–610.
6. Aminot, A., & Kerouel, R. (1997). Assessment of heat treatment for nutrient preservation in
seawater samples. Analytica Chimica Acta, 351, 299–309.
7. Gardolinski, P., Hanrahan, G., Achterberg, E., Gledhill, M., Tappin, A., House, A., et al.
(2001). Comparison of sample storage protocols for the determination of nutrients in natural
waters. Water Research, 35, 3670–3678.
8. Polya, D. A., Lythgoe, P. R., Abou-Shakra, F., Gault, A. G., Brydie, J. R., Webster, J. G., …
& Michailidis, K. M. (2003). IC-ICP-MS and IC-ICP-HEX-MS determination of arsenic
speciation in surface and groundwaters: Preservation and analytical issues. Mineralogical
Magazine, 67(2), 247–261
9. Wang, J. (2000). Analytical electrochemistry (2nd ed.). New York: Wiley.
10. Taillefert, M., Luther, G. W., & Nuzzio, D. B. (2000). The application of electrochemical
tools for in situ measurements in aquatic systems. Electroanalysis, 12, 401–412.
11. Bakker E., & Telting-Diaz, M. (2002). Electrochemical sensors. Analytical Chemistry, 74,
2781–2800.
12. Privett, B. J., Shin, J. H., & Schoenfisch, M. H. (2010). Electrochemical sensors. Analytical
Chemistry, 82, 4723–4741.
13. Iwasita, T., & DEM Pastor, E. (1994). Sand FTIR spectroscopic investigation of adsorbed
ethanol on polycrystalline platinum. Electrochimica Acta, 39, 531–537.
14. Rajeshwar, K., Ibanez, J. G., & Swain, G. M. (1994). Electrochemistry and the environment.
Journal of Appled Electrochemistry, 24, 1077–1091.
15. Schöning, M. J., & Kloock, J. P. (2007). About 20 years of silicon‐based thin‐film sensors
with chalcogenide glass materials for heavy metal analysis: Technological aspects of
fabrication and miniaturization. Electroanalysis: An International Journal Devoted to
Fundamental and Practical Aspects of Electroanalysis, 19(19–20), 2029–2038.
16. Frant, M. S., & Ross, J. W. (1966). Electrode for sensing fluoride ion activity in solution.
Science, 154, 1553–1555.
17. Wang, X. D., Shen, W., Cattrall, R. W., Nyberg, G. L., & Liesegang, J. (1996). The effects
of doping on the selectivity and response time of fluoride ion-selective electrodes. Australian
Journal of Chemistry, 49, 897–899.
18. Mascini, M., & Liberti, A. (1971). Preparation, analytical evaluation and applications of a
new heterogeneous membrane electrode for copper(II). Analytica Chimica Acta, 53, 202–
206.
19. Mascini, M., & Liberti, A. (1972). Preparation and analytical evaluation of a new lead(II)
heterogeneous membrane electrode. Analytica Chimica Acta, 60, 405–412.
20. Tan, J., Bergantin Jr, J. H., Merkoçi, A., Alegret, S., & Sevilla III, F. (2004). Oil dispersion
of AgI/Ag 2 S salts as a new electroactive material for potentiometric sensing of iodide and
cyanide. Sensors and Actuators B: Chemical, 101(1–2), 57–62.
21. Bakker, E., Bühlmann, P., & Pretsch, E. (1997). Carrier-based ion-selective electrodes and
bulk optodes. 1. General characteristics. Chemical Reviews, 97(8), 3083–3132.
22. Bobacka, J. (2006). Conducting polymer-based solid-state ion-selective electrodes.
Electroanalysis, 18, 7–18.
23. Rahman, M. A., Kumar, P., Park, D. S., & Shim, Y. B. (2008). Electrochemical sensors
based on organic conjugated polymers. Sensors, 8, 118–141.
24. Bobacka, J., Ivaska, A., & Lewenstam, A. (2003). Potentiometric ion sensors based on
conducting polymers. Electroanalysis, 15, 366–374.
25. Nair, S. G., & Hwang, S. T. (1991). Selective transport of calcium-ion from a mixed cation
solution through an HDEHP/n-dodecane supported liquid membrane. Journal of Membrane
Science, 64, 69–79.
26. Ross, J. W. (1967). Calcium-selective electrode with liquid ion exchanger. Science, 156,
1378–1379.
Materials in Electrochemical Detection of Water Pollutants
179
Précédent

- 186/320

Suivant